-40%
Power Supply Controller Meter Sensor Copper Crystal DC3.5~24V Digital Liquid
$ 24.13
- Description
- Size Guide
Description
Power Supply Controller Meter Sensor Copper Crystal DC3.5~24V Digital LiquidDESCRIPTION
Power Supply Controller Meter Sensor Copper Crystal DC3.5~24V Digital Liquid
Features:
- Brand new and high quality
- Made of high quality materials, durable
- Very easy to install, touch sensor, solenoid valve, power supply
- The temperature display range is -99°-999°. The units C is Celsius and F is Fahrenheit. temperature unit
- It can be switched by pressing the "+" key.
- usage time/flow display
- Automatically jump to the flow display when there is water, and display the total time when there is no water flow. Total time unit DAY
- It means days, HRS means hours, long press the "+" key to switch the time unit.
- The unit of measure is "l/min" for LPM and "gallon/min" for GPM. Short press the "-" key switch.
- Battery tips
- When the battery is low, the battery will flash, prompting the user to replace the battery. in electricity
- If the number is sufficient, it will not be displayed.
- When water is detected, the animation will start showing water droplets.
- Total water consumption, display
- Total water consumption expressed in liters L and gallons by gallons. When the total water consumption is less than When the total water consumption is greater than 9999.99 L (or GAL), 10000L (or GAL) will be accurate to two decimal places
- The decimal point will be hidden. The maximum measurement is 999999L (Note: if the upgrade, if the unit is set
- Entering the GAL, it is also considered to be 999999L cleared to 0, that is, remember to clear 219969GAL to 0), more in the future
- Remeasurement starts at 0.
- K value setting character (K SETTING)
- When entering the interface number, the K value setting character will be displayed: 00 is the K value setting interface (K SETING)
show
- Total character (TOTAL) After the system is powered on, the total flow character is displayed on the main screen.
Settings and interface description:
- How to set the system operating mode
- Use battery three AAA battery interface to power the system. (Batteries not included)
- Main interface and main interface settings
- Characters such as TOTAL, total water consumption, temperature, and total usage time will be displayed at the bottom of the main screen.
- Setting of K value setting interface and K value setting interface
- Short press the "SET" key once on the main interface to jump to the K value setting interface.
-“K SETTING”, interface number 00, K value are displayed under the K value setting screen.
- Press the "SET" key to set the K value in the K value setting interface. After long pressing the "SET" key, the first digit of the K value flashes, short press "+" and the flashing number increases by 1; short press "-" flashes the number minus 1; short press "SET"
- Press to switch to the next digit. After the setting is completed, long press the "SET" key to save the setting.
System sleep mechanism:
- When using the battery interface for power supply, in order to save energy and improve battery life, the system is unmanned
- If there is no water, it will go dormant. The monitor will automatically jump to sleep state
- The main interface and keep the display function. When there is water, it will automatically wake up the metering state.
- system reset
- There is a RESET symbol on the back of the board with two contacts next to it. Two contacts after system power up
- Short circuit for about 2 seconds, the system will restore the factory settings, clear the total time and total water consumption.
Specification:
- Water pressure resistance:>1.75MPa
- Range: 1-25L/min
- Interface size: 4 points (G1/2)
- Operating voltage range: DC3.5~24V
- Inner/Outer Diameter: 13.7/20.3mm
- Thread length Long thread: 16mm Short thread: 10.5mm
- Material : Copper
- Water pressure resistance: ≤1.75MPa
- Output pulse high level: >DC4.7V (input voltage DC5V)
- Output pulse duty cycle: 50%±10%
- Insulation resistance : >100MΩ
- Range : [at 1~25L\MIN]+3%
- Sealing seal the holes, add 1.7Mpa water pressure test for 1 minute without leakage and deformation
- Pulse characteristics (11*Q)Q=L/Min±3% or 660 pulses per liter of water
Package Included:
1*Instrument Controller
Notes:
1. Due to various factors such as display brightness and light brightness, the actual color of the product may be slightly different from the website picture.
2. Please allow a slight deviation between the data and the manual measurement.
POLICES
Shipping
Payment
WARRANTY
We only
ship to confirmed ebay Order addresses.
Please comfirm that your Order address is in line with your shipping address.
Please kindly note that
the c
ombined shipping
is not provided
because the shipping fee is calculated by weight. Also, the each additional item means
exactly
the the same color and size.
It takes about
7
-15 working days to US; about 10-30 working days to other countries.
Transit time may be a little delayed because of the
bad
weather and customs
inspection
. If you
do
not receive your
item
within 30 working days since payment finished, please contact us immediately for further assistance.
Payment must be completed within 5 days. If you have any problems about payment, please contact us via ebay message.
We strive for 100% customer satisfaction! Positive Feedback is very important to us. If you have any questions,
p
lease feel free to contact us via "Ask seller a question" . We will reply your email within 24
working hours.
On Nov 7, 2022 at 02:46:11 PST, seller added the following information: