-40%
Acuvim-KL-D-5A-P1 Power Meter
$ 94.72
- Description
- Size Guide
Description
Untitled DocumentAcuvim-KL-D-5A-P1 Power Meter
Model:
Acuvim-KL-D-5A-P1
| Order No:
Acuvim-KL-D-5A-P1
Acuvim-KL Power Meter with MODBUS RS485 output, plus integrated on-board LCD display, 5A input for current transformers and wide-range AC power supply input.
Brand:
Accuenergy
Model:
Acuvim-KL-D-5A-P1
Order No:
Acuvim-KL-D-5A-P1
Condition:
NEW
Description
Acuvim-KL-D-5A-P1 Power Meter
Accuenergy Acuvim KL-D-5A-P1 Offers
The Acuvim-KL is a compact electronic monitoring device that measures the consumed energy flowing through a circuit such as a standard 120V or 240V AC line and acts as a kWh calculator. The Acuvim-KL features Modbus RS485 serial connection. It also includes 5A current input, 100 to 415V AC, 50/60Hz, 100 to 300V DC power supply, and integrated LCD display.
Features
Measures basic power (kW, kVA, kVAr) and energy (kWh, kVAh, kVArh)
Meter and load running times
Included
Acuvim-KL-D-5A-P1 Power Meter
Specifications
Specifications
Metering
Parameters
Acuvim-L Accuracy
Acuvim-EL/KL Accuracy
Resolution
Range
Voltage
0.5%
0.5%
0.1V
20V~1000kV
Current
0.5%
0.5%
0.001A
0~50000A
Current Demand
0.5%
0.5%
0.001A
0~50000A
Power
1.0%
0.5%
1W
-9999MW~9999MW
Reactive Power
2.0%
0.5%
1var
-9999Mvar~9999Mvar
Apparent Power
1.0%
0.5%
0.001V
0~9999MVA
Power Demand
1.0%
0.5%
1W
-9999MW~9999MW
Reactive Power Demand
2.0%
0.5%
1var
-9999Mvar~9999Mvar
Apparent Power Demand
1.0%
1VA
1VA
0~9999MVA
Power Factor
1.0%
0.5%
0.001
-1.0~1.0
Frequency
0.2%
0.2%
0.01Hz
45.00~65.00Hz
Energy
0.5%
0.5%
0.1kWh
0~99999999.9kWh
Reactive Energy
2.0%
0.5%
0.1kvarh
0~99999999.9kvarh
Apparent Energy
1.0%
0.5%
0.1VAh
0~99999999.9kVAh
Harmonics
2.0%
-
0.01%
0~100.0%
Running Time
0.1hrs
0~999999999.9hrs
Communication
RS-485 (Option)
Modbus-RTU Protocol
2-wire connection, Half-duplex, Isolated
1200 to 38400 baud rate
Input
Current Inputs (Each Channel)
Nominal Current
5 A ac
Metering Range
0~6 A ac
Withstand
20Arms continuous100Arms for 1 second, non-recurring
Burden
0.05VA (typical) @5Arms
Pickup Current
10Vac
Accuracy
0.5%
Voltage Inputs (Each Channel)
Nominal Full Scale
400Vac L-N, 690Vac L-L (+20%)
Withstand
1500Vac continuous2500Vac, 50/60Hz for 1minute
Input Impedance
45Hz~65Hz
Pickup Voltage
10Vac
Accuracy
0.5%
Energy Accuracy (Acuvim-EL)
Active
(according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Reactive
(according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value
2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Control Power
Universal
AC or DC
AC/DC Control Power
Operating Range
100~415Vac, 50/60Hz, 100~300Vdc
Burden
3W
Withstand
3250Vac, 50/60Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range
20~60Vdx
Burden
3W
Digital Output Option
Digital Output (DO)
(Photo-MOS)
Voltage Range
0~250Vac/dc
Load Current
100mA (Max)
Output Frequency
25Hz, 50% Duty Ratio
Isolation Voltage
2500V
Digital Input Option
Digital Output (DI)
Input Voltage Range
20~250Vac/dc
Input Current (Max)
2mA
Start Voltage
15V
Stop Voltage
5V
Pulse Frequency (Max)
100Hz, 50% Duty Ratio
SOE Resolution
2ms
Operating Environment
Operation Temperature
-25°C to 70°C
Storage Temperature
-40°C to 85°C
Relative Humidity
5% to 95% non-condensing
Pollution Degree
2
Standard Compliance
Product
USA
UL 61010-1
Canada
cUL 61010-1
Europe
IEC 61010-1
Emission
Radiated/Conducted
FCC Part 15 Subpart B, Class A
Radiated/Conducted
EN 55011
Harmonic
IEC 61000-3-2
Voltage Fluctuation
IEC 50081-2
Radio Interference
IEC 50081-2
Immunity
ESD
IEC 61000-4-2
Radiated, radio-frequency, electromagnetic field
IEC 61000-4-3
Electrical fast transient/bust
IEC 61000-4-4
Surge
IEC 61000-4-5
Conducted disturbances
IEC 61000-4-6
Power frequency magnetic field
IEC 61000-4-8
Voltage dips and interruptions
IEC 61000-4-11
Generic Immunity Standard for Industrial Environment
EN 50082-2
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.